Burning smell from the consumer unit
This is the one fault that allows no waiting and no experimenting. If there is smoke, flame, or a strong smell: main switch off if you can, out of the property, and call 112. Do not go back in for belongings.
Right now
- 1Switch off the main isolatorThat is the only thing you should touch. If reaching the board means putting your face close to it, or you can see smoke, do not even do that — leave.
- 2Do not open the board coverOpening it feeds oxygen to a point that is already hot and puts your hands centimetres from live parts.
- 3Ventilate and get outOpen a window on your way past and leave the property. Burning PVC fumes are toxic long before there is any visible flame.
- 4Call 112 if there is smoke or flameWith visible smoke this is a fire-service emergency, not an electrician's. We come afterwards, once it is under control.
On call now · we reply in under 5 min
Request a QuoteWhy it happens
A loose terminal in the board
The dominant cause. An under-tightened screw creates resistance, resistance creates heat, and heat loosens the screw further. It takes weeks, and the sour smell of the plastic is the first external sign.
A degraded breaker or RCD
Internal contacts pit after many operations and begin to heat under normal load. It shows up on a thermal camera, not to the naked eye.
An overloaded extension lead or socket
Very common behind a TV unit or under a worktop. The smell comes from the socket rather than the board, but the mechanism is identical.
Undersized cable after refurbishment
A circuit extended without checking conductor size runs permanently at its limit. It heats along its whole length rather than at one point, and that is its distinguishing sign.
What we do on arrival
- We inspect the board with a thermal camera under load — the only way to see a hot spot before it announces itself.
- We re-torque every terminal with a torque screwdriver to the manufacturer's figure, not "firmly by hand".
- We replace the affected device or cable run; a terminal that has already charred the plastic is not recovered by re-tightening.
- We check whether the circuit was overloaded, because if that was the cause, fixing the point without fixing the load only postpones it.